Diagnostic Accuracy of Photon-Counting Detector CT Coronary Angiography for Coronary In-Stent Restenosis Compared with Invasive Coronary Angiography: A Systematic Review

Photon-Counting Detector CT Coronary CT Angiography In-Stent Restenosis Diagnostic Accuracy Systematic Review

Authors

November 25, 2026

Downloads

Coronary computed tomography angiography (CCTA) following coronary stent implantation is limited by metal-related artifacts, whereas photon-counting detector computed tomography (PCD-CT) offers improved spatial resolution. This systematic review evaluated the diagnostic accuracy of PCD-CT angiography for detecting in-stent restenosis (ISR) of ?50% luminal diameter stenosis using invasive coronary angiography (ICA) as the reference standard and summarized in vivo evidence regarding coronary stent visualization. Five electronic databases were searched from inception. Two reviewers independently screened studies, extracted relevant data, and assessed the risk of bias using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Findings were synthesized without meta-analysis in accordance with the Synthesis Without Meta-analysis (SWiM) reporting guideline, and the certainty of evidence was evaluated using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Twelve studies involving 511 patients were included, comprising eight diagnostic accuracy studies and four stent visualization studies. Five diagnostic accuracy studies provided complete 2 × 2 contingency table data for 560 stents or lesions. Sensitivity ranged from 75.0% to 100.0% (median: 96.3%), specificity from 83.0% to 98.7% (median: 90.4%), and negative predictive value from 91.7% to 100.0%. Positive predictive value was below 63% in four studies. The proportion of nonevaluable stents or lesions ranged from 0.9% to 6.8%. Ultra-high-resolution reconstruction improved specificity in within-study comparisons; however, seven of the eight diagnostic accuracy studies were assessed as having a high risk of bias, primarily due to selective verification. PCD-CT coronary angiography may be useful for ruling out clinically significant coronary in-stent restenosis in selected clinical settings. However, false-positive findings and low to very low certainty of evidence limit definitive conclusions regarding its clinical utility. Further prospective diagnostic accuracy studies incorporating complete verification with invasive coronary angiography are warranted.